For processes that require up to 10tons/hr of steam, the Titan AS represents our most popular model because of to its
versatility, robust construction and efficient operation.
Adopting the Reverse-Flame principle, the Titan AS allows hot flue gases to make 2 passes within its pressurised combustion chamber and a third and final pass through its fire-tubes on its exit, thus maximising the time and absorption of heat within the boiler.
Designed and manufactured to the latest international standards (BS2790)
Operating pressures of either 150psig or 250psig
Full wetback design thus minimising radiation heat loss and refractory maintenance
Spiral agitators in fire-tubes to enhance heat transfer
Large furnace volume assures high combustion efficiency and for a wide variety of fuels to be burnt efficiently
Compact in construction yet designed for easy access, important for internal inspection, cleaning and maintenance
Full automated operation provided for control for burner system, steam pressure and for failsafe operation